FLUSHING WITH SOLVENT
7 -
Immerse suction rod (L) and air shut off rod (O) into the material container.
8 -
Open air shut off valve (N).
9 -
Open the valve (H) of the pump air equipment to supply the air motor.
Nota : If the air motor is a 5000 or a 8000 version, it needs pilot air to operate. The pump air
equipment supplies pilot air to the air motor. The air supply pressure is adjusted previously in the
factory to 4 bars / 58 psi maximum.
10 - Increase the air regulator (D) so that the pump runs slowly (Pressure between 0.5 and 1 bar /
7.25 to 14.503 psi).
11 - Observe the drain (O); air bubbles come out from it. When bubbles no longer come out from it,
shut off the drain valve (N).
PRIMING WITH MATERIAL
12 - Remove suction rod (L) and drain rod (O) from material container and immerse them in a solvent
filled container.
13 - Open drain valve (N), wait until the material flows out regularly, then shut off the drain valve (N).
14 - Point the spray gun towards the material container and trigger the gun until the material flows out
regularly.
WORK
12 - Remove suction rod (L) and drain rod (O) from material container and immerse them in a solvent
filled container.
13 - Open drain valve (N), wait until the material flows out regularly, then shut off the drain valve (N).
14 - Point the spray gun towards the material container and trigger the gun until the material flows out
regularly.
Nota : Some of these pumps are designed for AIRMIX ® spraying when using long hoses and medium or
high viscosity fluids.
For this use, a spraying air kit shall be mounted on the pump air supply in order to feed compressed air to
the spray gun.

2-2 PUMP SUPPLIED IN FILLING (CIRCULATING)

Interconnect the fluid inlet of the pump with the circulating supply hose and start up the pump as it is
specified previously.
If the pump is a FLOWMAX ® one :
WARNING:
 Fluid section filling pressure :
 WARNING : Do not create overpressure.
 Never use the pump when an isolating gate on the supply circuit (upstream from the
FLOWMAX ® fluid section) is shut : it would damage the bellows.
 Do not install a material regulator on the supply circuit or any arrangement that could
perform as a non-return valve.
KREMLIN REXSON
2 bar maximum / 29 psi maximum
- 3 -
N° : 578.029.120-UK-1106