risk of explosion!
If the battery terminals are connected in re-
verse, the protection against swapped poles
ensures that the battery and the charger do
not get damaged. If this is the case, remove
the charger from the battery and from the so-
cket outlet. Start charging again after waiting
for approx. 3 minutes.
Calculating the charging time (Fig. 3)
The charging time depends on the charge status
of the battery. If the battery is fully discharged,
the approximate charging time up to approx. 80%
charged can be calculated using the following
formula:
Battery capacity in Ah
Charging time/h =
Amp. (charging current)
The charging current should be 1/10 to 1/6 of the
battery capacity.
Note! Gases are released during the charging
process. It is essential that you ventilate the
rooms well.
As long as the equipment is charging, the LCD
display shines green. If charging is complete, the
LCD display shines blue.
6.4 Finishing charging the battery
Pull the plug out of the socket.
First disconnect the black charging cable
from the bodywork.
Then release the red charging cable from the
positive pole on the battery.
Important! In case of positive earthing, first
disconnect the red charging cable from the
bodywork and then the black charging cable
from the battery.
Screw or push the battery stoppers back into
position (if there are any).
Anl_CC_BC_10_M_SPK1.indb 14
Anl_CC_BC_10_M_SPK1.indb 14
GB
6.5 Battery tester for 12V batteries
Connect the charger to the battery. The LCD
symbol "H" (Fig. 3) shows the charge status (1
increment = 25%). The battery voltage is shown
on the LCD display.

7. Overload cut-out

The charger is equipped with electronic protec-
tion against overload, short circuit and swapped
poles. One or more fi ne fuses are also fi tted. If the
fuse suff ers a defect it must be replaced by a new
fuse with the same amp value. If necessary, ple-
ase contact our customer service center.
8. Maintenance and care of the
battery
Ensure that your battery is always fitted se-
curely.
A perfect connection to the cable network of
the electrical system must be ensured at all
times.
Keep the battery clean and dry. Apply a thin
coating of grease to the connection terminals
using an acid-free, acid-resistant grease
(Vaseline).
Check the level of the acid in batteries that
are not maintenance-free versions approxi-
mately every 4 weeks and top up with distilled
water if necessary.
9. Cleaning, maintenance and
ordering of spare parts
Danger!
Always pull out the mains power plug before star-
ting any cleaning work.
9.1 Cleaning
Keep all safety devices, air vents and the
motor housing free of dirt and dust as far as
possible. Wipe the equipment with a clean
cloth or blow it with compressed air at low
pressure.
We recommend that you clean the device
immediately each time you have finished
using it.
Clean the equipment regularly with a moist
- 14 -