5. PC transfer
System requirements: Windows 7, Windows 8, Windows Vista, Windows XP SP3
Installation process:
• You will find the Healthcoach software download and installation in the download area at http://www.sanitas-online.de
• Follow the instructions for software installation.
Transfer data:
• Establish USB connection.
• Select data transfer in the software.

6. Incorrect measurement

If the scale detects an error during weighing, "FFFF" or "
If you step onto the scale before "0.0" appears in the display, the scale will not operate properly.
Possible causes of errors:
– The maximum load-bearing capacity of 180 kg (396 lbs) was
exceeded.
– The electrical resistance between the electrodes and the soles
of your feed is too high (e.g. with heavily callused skin).
– Your body fat lies outside the measurable range (less than 5%
or greater than 55%).
– Scale is on carpeting.
7. Disposal
Standard and rechargeable batteries should not be disposed of separately from the household waste. As a consumer, you are
legally obliged to return used batteries for proper disposal. You can hand in your used batteries at public collection points in
your district or sales outlets where batteries of this type are sold.
Note
The codes below are printed on batteries containing harmful substances: Pb = Battery contains lead, Cd = Battery
contains cadmium, Hg = Battery contains mercury.
For environmental reasons, do not dispose of the scale with the batteries in the household waste at the end of its
useful life. Dispose of the unit at a suitable local collection or recycling point. Observe the local regulations for mate-
rial disposal.
Dispose of the unit in accordance with EC Directive 2002/96/EC– WEEE (Waste Electrical and Electronic Equip-
ment). If you have any questions, please contact the local authorities responsible for waste disposal.
USB
" appears in the display.
Remedy:
– Only weigh the maximum permissible weight.
– Repeat weighing barefoot.
– Slightly moisten the soles of your feet if necessary. Remove the
calluses on the soles of your feet if necessary.
– Repeat weighing barefoot.
– Slightly moisten the soles of your feet if necessary.
– Place the scale on a level and solid surface.