A double active filter is also fitted inside the
basic filter on these models, Fig. 21.
Double
active filter
In order to remain operational, this filter needs
to be changed every year or when the
"change filter" symbol
screen.
(These accessories are available for purchase
from the Manufacturer's Official Technical
Service and authorised distributors).
Press the "+" and the "–" key at the same time
to make the symbol
screen after changing the filter. The symbol
disappears from the screen and the filter is
operational again.
Installing the double active filter:
J Remove the basic filter from the appliance,
Fig. 20.
J Change the double active filter inside the
basic filter for a new one as shown in Fig. 21.
J Install the assembly onto the appliance by
lining the lower studs up with the slots on
the front casing of the appliance and
pressing the top clip in until it clicks into
position. The assembly is fitted properly
when it clicks into position.
J Close the front flap.
Cleaning and Maintenance
Fig. 20
Fig. 21
appears on the
disappear from the
J In order to maintain cooling power, only fit
one set of filters onto the support.
Note
The flaps on these models are fitted with
safety stops up to which point they can be
opened without risk of the front flap falling
and causing damage and/or injury. The flap
on the appliance can be removed (firmly
pull the flap towards you) to make it easier
to clean and change the filters. Afterwards,
or should for any reason the flap come out
of its original housing, proceed as follows
to fit it:
1° Lift the flap until it comes out of its
lower supports, (Fig. 22: a).
2° Position the plastic leg in the front
groove on the appliance (in T position)
and slide it down to the safety stop,
(Fig. 22: b).
3° fit the lower studs in the front stops on
the appliance making sure that the
plastic leg fitted in the previous step
does not come out of position,
(Fig. 22: c).
When finished, the user should make sure
that the flap is fitted properly and does not
fall when opened again. (The door opens
up to the safety stop). If not fitted properly,
repeat steps 1° and 2° again.