Herunterladen Inhalt Inhalt Diese Seite drucken

Closing The Door; Installation; Electrical Connection - Electrolux SG248 Benutzerinformation

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

56 www.electrolux.com
Problem
upper or lower
square is shown
in the tempera-
ture display.

7.1 Closing the door

1.
Clean the door gaskets.
2.
If necessary, adjust the door. Refer to

"Installation".

8. INSTALLATION
WARNING!
Read the "Safety Information"
carefully for your safety and cor-
rect operation of the appliance
before installing the appliance.
8.1 Positioning
Install this appliance at a location where
the ambient temperature corresponds to
the climate class indicated on the rating
plate of the appliance:
Cli-
mate
class
SN
N
ST
T
8.2 Location
The appliance should be installed well
away from sources of heat such as radia-
tors, boilers, direct sunlight etc. Ensure
that air can circulate freely around the
back of the cabinet. To ensure best per-
formance, if the appliance is positioned
below an overhanging wall unit, the mini-
mum distance between the top of the
cabinet and the wall unit must be at least
100 mm . Ideally, however, the appliance
should not be positioned below overhang-
ing wall units. Accurate levelling is ensur-
Possible cause
An error has occurred in
measuring the temperature.
Ambient temperature
+10°C to + 32°C
+16°C to + 32°C
+16°C to + 38°C
+16°C to + 43°C
Solution
Call your service representa-
tive (the cooling system will
continue to keep food prod-
ucts cold, but temperature
adjustment will not be possi-
ble).
3.
If necessary, replace the defective
door gaskets. Contact the Service
Center.
ed by one or more adjustable feet at the
base of the cabinet.
WARNING!
It must be possible to disconnect
the appliance from the mains
power supply; the plug must
therefore be easily accessible after
installation.
A

8.3 Electrical connection

Before plugging in, ensure that the volt-
age and frequency shown on the rating
plate correspond to your domestic power
supply.
The appliance must be earthed. The pow-
er supply cable plug is provided with a
contact for this purpose. If the domestic
power supply socket is not earthed, con-
nect the appliance to a separate earth in
B