Herunterladen Inhalt Inhalt Diese Seite drucken

Service & Maintenance - Ferm PGM1008 Originalbetriebsanleitung

Vorschau ausblenden Andere Handbücher für PGM1008:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 8
EN
Clean up any spilled fuel
Do not smoke while operating the generator
Always use caution!
Starting the generator
Fig. 1 + 4 + 5
1. Turn on fuel tap (15).
2. Turn on engine switch (12).
3. Move choke lever (13) to closed position (to
restart a warm engine, leave the choke lever in
open or half-open position).
4. Pull slowly on the starter cord until it engages,
then pull sharply to start the engine (14).
5. Allow the engine to run until it warms up, and
then move the choke lever to the open position
(13).
Using the AC Output (230 V)
Start the generator.
Plug in the electrical appliance plug.
Press AC current protector downward to
"ON"(7).
The voltmeter (11) displays the voltage on the
AC socket. Normally this should be ± 230 V
during use.
Stopping the generator
Fig. 1 + 5
1. Unplug all cords (5)
2. Turn engine switch to "OFF" (12)
3. Turn off fuel tap (15)
4. Service & Maintenance
Periodic maintenance
Daily (pre-operation check)
Check engine oil level
Check fuel hose for cracks or other damage.
Replace if necessary.
Check exhaust-system for leakage. Retighten
or replace gasket if necessary.
Check choke operation
Check recoil starter operation
1st Month or 20 hrs
Replace engine oil
3 Months or 50 hrs
Check condition of spark plug. Adjust gap and
clean. Replace if necessary.
Clean, replace if necessary.
6
6 Months or 100 hrs
Replace engine oil
Clean fuel tap and fuel tank filter. Replace if
necessary.
Check fittings and fasteners. Replace if
necessary.
12 Months or 300 hrs
Contact a specialized service centre to check
the valve clearance.
Check the fan of the cooling system for
damage.
Service – notes on maintenance
Fig.1
Oil replacement
Warm up engine on level ground
Remove filler cap (8)
Open drain plug (9) and let oil drain completely
into a pan placed under the engine.
Check gaskets, replace if required. Refit drain
plug and refill engine with clean oil.
Replace filler cap.
Spark plug inspection
Fig. 3
Disconnect the spark plug cap, and remove
any dirt from around the spark plug area.
Remove spark plug (17) with the plug spanner
supplied.
Inspect the spark plug. It should be a tan
colour.
Measure the gap (distance contact point) with
a suitable gauge. The gap should be 0,7 - 0,8
mm. Correct the gap, if necessary, by carefully
bending the side electrode.
Replace the spark plug if the electrodes are
worn, or if the insulator is cracked or chipped.
Install the spark plug carefully, by hand, to
avoid cross-threading.
Place the spark plug with correct torque: 20
Nm.
Attach the spark plug cap.
exhaust screen
Wait for exhaust to cool.
Exhaust screen may be blocked up with
carbon deposits.
Undo the screw cap and remove the exhaust
screen.
Clean the screen with a wire brush and refit.
Replace exhaust screen if damaged.
Air filter cleaning
Ferm

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Pgm1012

Inhaltsverzeichnis