Keep bystanders away
Do not expose to rain
Outdoor noise
Risk of high temperature
Caution: the generator contains some
parts which might reach high
temperatures
Safety instructions
Persons
Never allow children or people unfamiliar with
these instructions to use the appliance. Local
regulations may restrict the age of the
operator.
Always operate outdoors with good ventilation.
Exhaust gas contains poisonous carbon
monoxide.
Always stop the engine before refilling the fuel
tank and clean the machine after filling the fuel
tank.
Do not inhale fumes from petrol.
Electricity
Do not touch the generator if you have wet
hands
Do not operate the generator in wet conditions.
Do not operate the generator near water.
Never connect two generators together.
Never connect the generator to any
commercial power outlet.
Make sure any extension cords used are in a
safe condition and of sufficient capacity for the
task.
Ensure that the load on the generator falls
within its capacity as specified in the table
before plugging in any cords.
Fire and burn hazards
The exhaust system gets hot enough to ignite
some materials:
keep the generator at least 1 meter away
from buildings and other equipment during
operation.
keep flammable materials away from the
Ferm
generator.
The exhaust becomes very hot during
operations and remains hot for a while after
stopping the engine:
Let the engine cool before storing the
generator indoors.
Do not touch the hot exhaust with your
hands.
Gasoline is extremely flammable and is
explosive under certain conditions. Do not
smoke or allow flames or sparks where the
generator is refueled or where gasoline is
stored.
Fuel vapors are extremely flammable and may
ignite after the engine has started. Make sure
that any spilled fuel has been wiped up before
starting the generator.
Never shade the generator with clothes or
other articles.
3. Use
Before starting the generator

Ground terminal

The generator ground terminal is
connected to the frame of the generator,
the metal non-current-carrying parts of
the generator, and the ground terminals of
each receptacle. Before using the ground
terminal, consult a qualified electrician,
electrical inspector or local agency having
jurisdiction for local codes or ordinances
that apply to the intended use of the
generator.
Fill and check oil level (quantity is 600 ml)
Always check the oil level (with machine in a level
position) before starting and if the engine
unexpectedly stops (fig. 2).
For general use you can use an "all temperature"
oil 10W-30
≤ 0ºC
0ºC - 25 ºC
25ºC -35 ºC
≥ 35ºC
Fill and check fuel level
Use unleaded fuel only
Remove any power cords
Turn power switches off
Do not overfill – leave air gap at top of fuel level
Always screw down fuel cap
EN
SAE#10
SAE#20
SAE#30
SAE#40
5