Closing the setting up of
a radio group
The setting up of a radio group is nor-
mally automatically closed 10 minutes
after the activation of the connection
mode for the smoke alarm device with
radio link planned last for the radio
group so that the radio group is activa-
ted when none of the devices gives out
any signal through the radio LED.
If all smoke alarm devices with radio
links planned for making a radio group
have been connected to a radio group
as described above, the connection mo-
de can be alternatively ended directly
by short press of the radio button (Illus.
6 point a) of any smoke alarm device
with radio link in the radio group. The
radio LEDs of all smoke alarm devices
with radio links switch off. The radio
group is now activated.
en
Functions test of the
radio group
The correct connection of the radio
group can be easily controlled with the
test/stop button (Illus. 1 point d) of a
smoke alarm device with radio link.
A short confirmation of the test/stop
button (Illus. 1 point d) for 2-3 seconds
will initiate a self-test of the individu-
al device. A short signal will be given
out now.
A longer pressure on the test/stop
button (Illus. 1 point d) until the second
signal will initiate self test via radio in
all other smoke alarm devices with
radio links in the radio group. This test
needs to be repeated every 3-6 months
in order to test the radio group's
functioning.