Herunterladen Inhalt Inhalt Diese Seite drucken

Normal Functioning - LA NORDICA CLEO COMBI Bordeaux Installation, Inbetriebnahme Und Wartungsanleitung

Kombi-kaminofen
Vorschau ausblenden Andere Handbücher für CLEO COMBI Bordeaux:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

1) Open the lateral access hatch to the mechanical parts (L Picture 9); if the lever (C) is already in position P
(PELLET) go to point 3);
2) With the use of the poker in the position D, lift the latch and decontrol the lever (C) push it toward the front side of
the stoves in the position marked with the letter P and stop it
with the latch (D) in the position 2 shown in Figure 2; cast iron
grate (G)in upright position;
3) check that the hatch of the pellet feeding tank (S) is closed
and locked using the handle (B);
4) close the lateral access door(L) to the mechanical parts.
ATTENTION: before lighting, the stove must be as in the
original state, i.e. with the side door and the tank lid closed
using the handle.
The lighting procedure is manual and envisions the following
points:
IMPORTANT: for correct and uniform lighting, it is necessary to
use a pair of fire-lighter cubes (Picture 10 pos.1 pos.2).
Check that the register of the primary air is completely
open;
Open the upper door;
Place the relevant supplied chute (Picture 10 pos.A) on
the grate and in the rear edge of the burner caps (pos.1
pos.2);
Place a fire-lighter cube on the chute, light it and make it
slide inside the burner;
When the two cubes have been lit in pos.1 and pos.2,
remove the chute and close the fire door.
ATTENTION: do not use any inflammable liquids for lighting.
When lighting has taken place, the user can adjust the heating power through the primary air register (R) from the
minimum power (register towards left) to the maximum power (register towards right completely open).
ATTENTION:
• The lid of the pellet container must always be closed. It must only
be opened during the fuel feeding phase.
• The bags of pellets must be kept at least 1.5 metres from the
stove.
• Do not allow the bag of pellets to come into contact with the
boiling hot stove during the filling phase

10. NORMAL FUNCTIONING

During normal stove functioning of the pellet stove, the cinders must be
shaken to prevent stratification of the ash. (see par. 14.3 – 14.4)
The appliances with automatic door closure (type 1) must function, for
safety reasons, with the hearth door closed (except for the fuel feeding
phase or removal of ash).
The appliances with constructive system type 2 must be connected to
their own flue. The operating with open door is allowed under supervision.
IMPORTANT: For safety reasons, the hearth door can only be
opened when feeding the fuel. The hearth must remain closed
during functioning and standstill periods.
The nominal calorific value of the stove is equal to 6.4kw-wood / 6kw-
pellet and is reached with minimum draught (depression) of 12 Pa (= 1.2
mm of water column).
Using the registers ( R ) on the stove face (Picture 1) regulate the emission of heat from the hearth.
These must be opened according to the heat requirement.
Never overfeed the stove (consult the technical table – max. quantity of fuel that can be fed).
28
S
B
L
G
1
2
CB
G
A
8192000 Rev.08 – EN
CLEO COMBI.
2
P
C
D
Picture 9