The durability of the installation depends very much on the material used at the installation area (building
material) such as wood, concrete, gas concrete, brick etc. This is why the fixing material must be chosen to
suit the wall material. Always ask a specialist for the correct plug/screw combination indicating the maximum
load and the building material.
Procedure:
Step 1: The fixation holes are located on the baseplate.
Step 2: Hold the baseplate onto the location where the device is to be installed.
Step 3: Mark the boreholes with a pen or a suitable tool.
Step 4: Drill the holes.
Step 5: Hold the baseplate in the desired position and tighten it.
The installation material must never include abrading material e. g. steel cables in order to avoid
The length of the chain must never exceed 100 cm.
Install the mirror ball chain with the screw-on chain link at the installation eyelet of the mirror ball and tighten
the fixation screw.
Insert the mirror ball chain with the mirror ball in the screw-on chain link and tighten the fixation screw.
Make sure that the rotation of the mirror ball is never slowed down or stopped by decoration material etc.
Make sure that no side forces can impact on the installation.
Make sure that the mirror ball cannot be moved by air streams. The mirror ball and the motor must be
installed and operated absolutely swivel free.
Please check in regular intervals, if the key ring or chain links have been deformed. Uninstall the mirror ball
immediately in such a case.

Connection with the mains

Connect the device to the mains with the power plug. The occupation of the connection cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green Earth
Attention! The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Before taking into operation for the first time, the installation has to be approved by an expert!
material wearing.
International
L
N
DANGER TO LIFE!
21/23
00056204.DOC, Version 3.1