Further recordings
• If the drive and heating remain switched on, a new file will be created and the process values will be recorded
every time the clamping lever is activated.
• If the drive is switched off, no new file will be created and there will be no recording of the process values
after the clamping lever is activated.
• If the values are not to be recorded any more, the USB stick must be removed
• Check the remaining memory of the USB stick on the PC from time to time.
Evaluation
• Insert USB stick into USB port of a computer (not supplied).
• Start spreadsheet software (not supplied).
• Open file
• Select drive (drive with USB stick)
• File type: «all files»
• Select and open the desired recorded file (*.csv)
• The file opens. Example of file content:
Header
Data
Client text (can be edited)
Number of recording file
Recording interval
Column headings
Unit
1. Record
another record every 5cm
Company XY
File-number:
0218-002
LEISTER Switzerland
Software Relase 2.0B
Date:
18.02.2009
Time:
14:59:13
v =
3.2m/min
t =
560°C
intervall =
5cm
Distance
Speed
Temperature
[cm]
v[m/min]
0
3.2
5
3.2
10
3.2
15
3.2
20
3.2
25
3.2
30
3.2
35
3.2
40
3.2
45
3.2
50
3.2
55
3.2
Force
T[°C]
F[N]
559
750
559
920
559
920
559
975
559
990
559
990
559
995
559
995
559
995
559
995
559
995
559
995