Herunterladen Inhalt Inhalt Diese Seite drucken

Cleaning And Maintenance; Daily Cleaning After Completion Of The Slaughters - EFA 63 Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Malfunction
Saw is unusually loud
(motor or gear head)
Brush sparking in motor
Saw blade "wobbles"
No cutting performance

6. Cleaning and maintenance

Disconnect the machine from the
works mains before all cleaning
and maintenance work!
6.1 Daily cleaning after completion
of the slaughters
Continuous reliable operation can only be assured if
the reciprocating saw is kept hygienically clean at all
times. The machine should normally be disinfected
before each cleaning.
Observe the applicable safety and hygiene regula-
tions (EN 1672)!
Disinfectants must not be allowed to come into di-
rect or indirect contact with foodstuffs. Rinse the
machine with clear water after disinfection.
The saw blade must be removed as described in
chapter 4.1 for disinfection and cleaning. For this,
move the saw from the breaking room to the main-
tenance station.
Schmid & Wezel
D-75433 Maulbronn
Table 1: Troubleshooting
Possible cause
18. Motor bearings (7+9) defective
19. Bearings in gear head defective
(4,13, 20 + 29)
20. Paired bearings (13) incorrectly installed
21. Hollow wheel (31) or gear wheel vst
(28)
Teeth worn
22. Armature (8) soiled or defective
23. Carbon brushes (16) worn
24. Saw blade (36) or guide (33) not cor-
rectly installed or secured
25. Bearing (4) defective
26. Saw blade (36) blunt
Seite/ Page
18/ 30
Inspect, replace if necessary
Inspect, replace if necessary
Inspect and install correctly
Position spacer ring (14) against
wide outer ring
Inspect, replace if necessary
Inspect and clean armature (see
chapter 4.3), replace if
necessary
Inspect, replace if necessary
(see chapter 4.3)
Inspect mounting and replace, if
necessary, secure with nut
„<> right assembly"
Inspect, replace if necessary
Sharpen or replace saw blade
Do not use aggressive solvents!
Do not use steam or high-pres-
sure cleaners! Do not immerse the
machine in water!
6.1.1 Disinfection
Disinfect the machine during operation after every
cut with hot water (82° C).
Always perform disinfection separately from
cleaning. Always allow the disinfectant to work for
20-30 minutes.
6.1.2 Cleaning of the reciprocating saw
Clean the machine after use with a cloth, brush and
warm water (40 - 55° C). Stubborn or encrusted
soiling must be soaked beforehand. Clean using a
cleaning agent, preferably as a foam, that is applied
to the surface to be cleaned and allowed to work for
15 - 20 minutes. Subsequently wash off the dis-
solved soiling manually with warm water.
Remedy
Ausführung/ Version
10.2007

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis