3.3.1 Working procedure

Before putting the saw into operation, check the rat-
ings of the power supply network and of the saw for
correspondence. Carry out a function test before
starting work.
Hold the guide and saw blade as
straight
sawing. Do not allow to bend!
Improper
increased wear!
Hold the saw firmly, position correctly and press
the trigger switch (see chapter 3.2)

3.3.2 Work safety

Hold the machine firmly with both handles,
never work one-handed.
Never carry the saw at the switch; it might start
unintentionally.
Hold the guide and saw blade as straight as pos-
sible during sawing and do not allow to bend.
Handle particularly carefully during sawing.
Put the saw down only when the saw blade has
come to a complete standstill (run-down time
approx. 3 s)
For safe operation (guidance), the reciprocating
saw must be suspended from a spring balancer.

4. Assembly

Disconnect the saw from the
mains power supply before all
assembly work.
The drawings necessary for assembly can be found
in A.3.

4.1 Changing the saw blade

Use only original EFA saw blades!
Schmid & Wezel
D-75433 Maulbronn
as
possible
during
use
will
result
Loosen hex. nut (1) and remove the saw blade
by swinging out to the side by hand. (see Fig. 3)
Replace the saw blade and install in the reverse
order, lubricate saw blade guide (2) with special
grease 001 365 623.
2
in
Figure 3: Saw blade changing
Observe the tightening torque of 4.9 Nm.
Before putting the saw into operation again, carry
out a test run. Pay attention to secure mounting of
the saw blade.

4.2 Sharpening the saw blade

Incorrectly sharpened saw blades detract from your
productivity and also constitute considerable risks
for the user.
Sharpening can be carried out on commercially
available automatic saw blade sharpening ma-
chines.
Technical data - saw blade:
Length
No. of teeth
Tooth set
Order No.
Seite/ Page
15/ 30
1
350 mm
55
-