17. WARNING MESSAGES ON THE DISPLAY

REVERSE POLARITY
CONNECTION BREAK
SHORT ERR
PLS. RESTART
VOL SELECT ERR
BREAK DOWN
BATTERY CHECK
LOW VOLTAGE
BATTERY CHECK
HIGH VOLTAGE
BATTERY CHECK
CELL LOW VOL
BATTERY VOLTAGE
CELL HIGH VOL
The polarity of the battery poles has been reversed.
The connection to the battery has been broken, e.g. if the
battery has been disconnected during the charging process.
A short-circuit has been established on the charger output.
The input voltage (operating voltage) for the charger is too
low.
The voltage of the LiPo, LiIon, LiFe battery to be charged is
incorrectly configured.
The charger has established that there is an internal problem.
Should this message be displayed permanently, it is possible
that the charger is defective; have it checked by a specialist
workshop or qualified technician.
The voltage is lower than which is set. Check if the voltage of
the battery has been correctly configured.
The voltage is higher than which is set. Check if the voltage of
the battery has been correctly configured.
The voltage in one of the cells of a LiPo, LiIon, LiFe battery is
too low. This can occur if a multicell battery has been charged
previously without a balancer.
The voltage in one of the cells of a LiPo, LiIon, LiFe battery is
too high. This can occur if a multicell battery has been charged
previously without a balancer.