f) Discharging batteries ("DISCHARGE")

Normally, it is not necessary to discharge lithium batteries (contrary to NiCd batteries). The battery can
be charged immediately regardless of its current status.
To discharge, you can set the discharge current between 0.1A and 1.0A.
Proceed as described in chapter 11.b) with the difference being the batteries are being discharged,
not charged.
The final discharge voltage differs depending on the battery type and is already preset in the charger.
In addition to the battery type, the display shows the corresponding voltage.
• LiPo: 3.0V per cell
• LiIon: 2.5V per cell
• LiFe: 2.0V per cell
If a multi-cell battery is connected via the balancer connections, you can switch between
the normal display and the display of the cell voltages during the discharge process with
the „INC" button.