5. To begin the charging process, keep the "Start/Enter" button pressed (approx. 3 seconds).
6. If the settings are wrong, or if the charger detects a problem, an audio signal is emitted and the
appropriate information is shown on the display.
7. You can stop the audio signal by pressing the "Batt Type/Stop" button. You then return to the
previous configuration menu.
8. If the battery is detected correctly, the following display appears, for example:
Battery type / Charge current / Battery voltage
Pb-6 0.5A 12.59V
CHG 022:20 00207
Current charging duration
9. Once the charging process has been completed, an audio signal is emitted (if not turned off).
If you wish to terminate the charging process beforehand, press the „Batt Type/ Stop"
button.

c) Discharging batteries ("DISCHARGE")

1. After you have selected the "Pb" program in the main menu with the button "Batt Type/Stop" and
confirmed this with the button "Start/Enter", you can select the discharge function using the button
"INC" or "DEC":
Pb DISCHARGE
0.1A
12.0V(6P)
The value on the left in the second line shows the discharge current, the value on the right shows the
voltage or number of cells of the battery (in this example, a 6-cell lead battery, 6x 2.0V = 12.0V).
2. If the values need to be changed, press the "Start/Enter" button. The discharge current blinks.
Change the discharge current using the buttons "INC" and "DEC", confirm the value using the
"Start/Enter" button.
3. The voltage/cell number then begins to flash. Change it using the buttons "INC" and "DEC". You
should be aware while doing this that the voltage only changes with the number of cells (e.g. one
cell = 2.0V, two cells 4.0V etc.) Confirm the setting by pressing the "Start/Enter" button.
The charger sets the final discharge voltage automatically for safety reasons.
4. To begin the discharge process, keep the "Start/Enter" button pressed (approx. 3 seconds).
5. If the settings are wrong, or if the charger detects a problem, an audio signal is emitted and the
appropriate information is shown on the display.
6. You can stop the audio signal by pressing the "Batt Type/Stop" button. You then return to the
previous configuration menu.
62
Charge capacity in mAh