Setting the Sensitivity of delta-U detection of NiMH ccumulators
NiMH Sensitivity
D.Peak 10mV/Cell
Here you can set the sensitivity of the delta-U detection of NiMH batteries (voltage difference in the
delta-U charge procedure).
You can select the voltage value (5 to 20mV). If you select "DEFAULT", the charger uses a voltage of 7mV.
An excess value may overcharge the battery. If the value is not high enough, the battery
may not be charged sufficiently.
Setting the Sensitivity of Delta-U Detection of NiCd Batteries
NiCd Sensitivity
D.Peak
Here you can set the sensitivity of the delta-U detection of NiCd batteries (voltage difference in the
delta-U charge procedure).
You can select the voltage value (5 to 20mV). If you select "DEFAULT", the charger uses a voltage
of 12mV.
An excess value may overcharge the battery. If the value is not high
enough, the battery may not be charged sufficiently.
Setting the Temperature Cut-off
Temp Cut-Off
ON 80C 176F
The small 3-pole connection of the charger serves to connect a temperature sensor. You can switch
the temperature sensor on or off.
You can turn this function ON or OFF. If it is turned ON, you can then set the temperature at which
a subsequent charge or discharge process will be terminated. The adjustable range is in between
20ºC to 80ºC.
Setting the Cooling Time
Waste Time
CHG>DCHG
The battery may become quite hot using the cycle program (automatic charge/ discharge cycles in
sequence).
You can select a break time here to allow the battery to cool off sufficiently.