The information to read out of the access cards has to be selected to suit the
communication interface.
DIP 7
DIP 8
off
off
Note: Unique serial number is also known as Unique Identifier. The first 4 bytes of
any card serial number are transmitted (i.e all of a Mifare Classic serial number but
only part of the DESfire EV1 serial number). This 4 byte data is converted to its deci-
mal equivalent for transmission. If Wiegand interface is used, parity bits are omitted
from output messages.
DIP 7
DIP 8
off
on
Note: For the reader to transmit 7 byte UID it is necessary also to select ASCII-
Minimal protocol. Omron interfaces, also known as Mag stripe or Clock/Data, are not
supported. If Wiegand interface is used, parity bits are omitted from output messages.
DIP 7
DIP 8
on
off
Note: For the reader to transmit BCD ID it is necessary also to select ASCII-Minimal
protocol, otherwise no data are transmitted. Omron interfaces, also known as Mag
stripe or Clock/Data, are not supported. If Wiegand interface is used, parity bits are
omitted from output messages.
Please note:
The ID-number is a BCD format (4bit) number written by the user into the
read/write area of the Mifare Classic (sector/ block) or Mifare DESFire EV1 (data
file) access cards. Each 4 bit character is limited to the digits 0-9.
RS485 electrical signals may be connected to models DC2000 or K24 and mes-
sages sent under the UCI protocol. Please note that this connection supports Mi-
fare Classic cards but does not support Mifare DESfire EV1 cards.
RS485 electrical signals may be connected to models DC2000, CC30xx, DRI or
ERI and messages sent under the CerPass-protocol.
The data length of the ID number is limited to 10 digits if the reader is connected to
CC30xx. However in a SiPass integrated system it is possible to transmit 16 digits.
Information to read
4 byte Serial number (UID)
Information to read
7 byte Serial Number (UID)
Information to read
ID-Number, BCD coded and
connected via RS-485
Card type
Mifare Classic
Card type
Mifare Classic, Mifare
DESFire EV1
Card type
Mifare Classic, Mifare
DESFire EV1