4-2-2. Two-direction origin method (only standard specification)
When connected to a LH41 counter
When the head carrier passes the origin mark from either direction, a 16 ms pulse is generated.
SR801R
16ms
4-3. Others
For sections where the couplings causes a difference in height (sections A and B, below), the
origin mark cannot be lined up with the zero point position. In this case, confirm with the origin
position display of the Absolute Zero Point on the effective length label (see page 33).
SR801R
A
B
35