Herunterladen Inhalt Inhalt Diese Seite drucken

Funktionsoptionen; Systemmenüs - Manitowoc Garland MWE2W Installation Und Betriebsanleitung

Vorschau ausblenden Andere Handbücher für Garland MWE2W:
Inhaltsverzeichnis

Werbung

GARLAND CLAMSHELL-GRILLS MIT PRODUKTERKENNUNG
FUNKTIONSOPTIONEN; SYSTEMMENÜS
FUNKTIONSOPTIONEN; SYSTEMMENÜS
SOFTWARE V202
System Menu
Sub Menu
Configure Menu
Grill Type
Platen Enabled
Grill Region
Cook Zone
More Multi Gap
Auto Standby Timer
Auto Standby Delay
Setup
Temperature Units
Time Unit
Key Chirp
Audible
Audio Volume
Reload Defaults
Multi Gap
Audible Select
Auto Mode Enable
Product Rec Timeout
Heather Err Timer
Too Cool Lo Lmt
Calibration
Level / Reed Switch
Auto Gap Force
Probe Cal
Gap Calibration
Reed Switch Min
Reed Switch Max
Delta Speed Err
Pivot End Mills
Show Reed Data
Front Reed Cal
Back Reed Cal
F ZERO Cal
B ZERO Cal
F ARM OFFSET_MIN
Cal Delta Percent
DIAGNOSTIC
Date Code
Serial Number
Part Number
App VERSION
CLM 1 Version
CLM 2 Version
Audio Version
Motor Version
Ambient 1
Ambien 2
Ambient 3
Top Probe
Grill Probe F
Grill Probe M
Grill Probe B
External probe
PR Front Detect
PR Back Detect
PR Table Value
Service
Encoder Counts
Motor Status
Switch Status
Startup Rate
Buss Voltage
Motor Max Speed
Motor Revision
Motor Error
Lonworks Service
TEILENUMMER 4526903 (09/01/10)
Options
Electric
Setting that tells control whether grill is electric or gas. Must be set correctly to identify number of heat zones.
Gas
Yes
Setting in control that tells whether platen is present. I.E: Flat grills (No Platens).
No
World
Setting to determine regional setup requirements.
Japan
Left
Center
Placement of control on grill.
Right
Yes
Current requirements are for 2 stages of gap. This setting when set to Yes shows all 3 additional multi gap settings.
No
On
Turns on/off the automatic alarm to alert the operator to put grill in standby.
Off
1-5
Seconds in which alarm will sound when alerting operator to put grill in standby.
F (Fahrenheit)
Setting to display temperature units in Fahrenheit or Celcius.
C (Celcius)
sss
Setting to display time Units:
mss
sss - Seconds
mmm
mss - Minutes / Seconds (M:SS)
Yes
Setting that turns the sound on/off when a button is pressed.
No
3 Second
Strobe
Audible sound when remove alarm is sounding.
Song
1-100 (Adjustable)
Alarm volume
Yes
When Yes is selected, the control will automatically begin to reload its factory defaults. In this setting, only menu item defaults are
No
reloaded.
Yes
Enabled Multi Gap cooking on or off.
No
0
1
Pitch of tone in controller
2
Yes
Enables or disables product recognition cooking in control.
No
0-30
Maximum number of seconds to recognize product. If product is not recognized in [Product Rec Timout} time, then "Product Not Rec"
60-1200
Number of seconds the controller must see a temperature rise before "Heater Error"
OFF , 1F/C-450F / 250C
Yes
Mode where technician performs Platen Leveling procedure, and Reed Switch Calibration procedure
No
Yes
Mode where user can perform an Auto Calibration upon request.
No
All Temperature Zones
Mode to perform a temperature probe calibration
-1000 - 1000
Gap Offset - Offsets Gap setting for all menu items.
0 - 1000
Maximum Δ CAL before warning / error msg
0 - 1000
Maximum Δ CAL before disabling clam operation.
Number corresponds to linear actuator motor speed.
0-20
Adjusts automatically.
Number set corresponds to location of pivot block to determine pivot point and decreased motor speed.
800 - 3000
YES/NO
When activated to YES, controller will display encoder counts when reed switches close.
During Auto Calibration, the encoder counts when Front Reed Switch Closed.
During Auto Calibration, the encoder counts when Back Reed Switch Closed.
During Auto Calibration, the encoder counts when Front Reed Switch Opened.
During Auto Calibration, the encoder counts when Back Reed Switch Opened.
-3000 - 1000
Calculated Offset of arm deflection.
Factor of error calculated in control.
INSTALLATIONS- UND BETRIEBSANLEITUNG
Description of Options
Default
Electric
Yes
World
Left
Yes
OFF
3
F
sss
Yes
3 second
100
No
Yes
1
Yes
10
425
110F / 61C
No
No
0
200
300
1100
No
-20
25%
Seite 35 35

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Garland mwe2s

Inhaltsverzeichnis