Herunterladen Inhalt Inhalt Diese Seite drucken

Order Code - HBM u5 Montageanleitung

Vorschau ausblenden Andere Handbücher für u5:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

U5
• Cable with sub‐D male connector
Top view
Fig. 6.4: Sub‐D male connector assignment
The cable shielding is connected in accordance with the Greenline concept.
This means that the measurement system is surrounded by a Faraday cage
and is not affected by electromagnetic interference.
Connectors to CE standard are to be fitted at the free cable end of the
transducer. The shielding is here to be laid over the whole area. If a different
connection technique is used then good EMC shielding is to be provided in
the wiring loom, the shielding again being laid over the full area (see also
HBM Greenline Information, document G36.35.0).

6.1 Order code

Code Option 1: Measuring range
100 K Measuring range 100 kN
200 K Measuring range 200 kN
500 K Measuring range 500 kN
K-U5-
A0809-8.0 en/de/fr
Sub‐D con­
nector pin
1
2
3
4
13
12
Code Option 2: Electrical connection
K
with cable, 6 m, free ends
M
with cable, 6 m, MS connector (male)
D
with cable, 6 m, D15 connector
Y
with cable, any length, max. 20 m, free ends
N
with cable, any length, max. 20 m, MS connector (male)
F
with cable, any length, max. 20 m, D15 connector
P
with Binder 723 male connector
m
-
Order code: D or F
Assignment
Measurement signal (+)
Excitation voltage (-)
Excitation voltage (+)
Measurement signal (-)
Sensor circuit (+)
Sensor circuit (-)
17
Wire
colour
WH
BK
BU
RD
GN
GY
HBM