Function
Via Dip-Switch different functions can be adjusted individually:
Dip 1
position "ON" =
Maximum flushing time see time potentiometer
Dip 1 and 2 position "ON":
Dip 2
position "OFF":
Dip 3
Program Comfort & Self-close:
position "ON":
position "OFF":
Program Automatic:
position "ON":
position "OFF":
Dip 4
position "ON":
position "OFF":
Dip 5
position "ON":
position "OFF":
Dip 6
position "ON":
position "OFF":
Dips 3, 4, und 5 can be adjusted at the programs individually.
* Hygiene flushing can be activated, so that in the lines no stagnation water remains long time.
After 24 h without use an automatic flushing will be released for 10 s.
shower-function
Waterflow starts, when the user releases by close active
range (Dip 6 "ON"), or if user releases via push-button
(Dip 6 "OFF") and remains as long as the user stays
in the infrared active range.
Minimum of switch-on time 10 s if the last activation is
more than 20 min ago (-> hot water)
The user is recognised as soon as he gets into the infrared
active range. The water flow remains as long as the user
stays in the infrared active range.
Self-close function activated
Self-close function deactivated
Cleaning stop can be activated by 5 close range
reflex impulses for 3 min
Cleaning stop can not be activated
Continuous flow can be activated by 3 close range
reflex impulses for adjusted flushing time (if Dip 6 „OFF"
release waterflow via push button first). Stop continuous
flow via 3 anew reflex impulses.
Continuous flow can not be activated
Hygiene flushing* after 24 hours without use
No hygiene flushing
Activation by close range reflex (Dip 2 "ON")
Activation by push-button (Dip 2 "ON")