Device adjustments

GB

Front side:

Active range potentiometer
1
infrared active range
(adjustable from 20 - 70 cm)
2
Time potentiometer
maximum flushing time from 30 s - 10 min
adjustable
Diagnose LED
3
- flashes slowly if operating voltage is too low
(<5,0 V)
- flashes at close range reflex
12
2
1
7
4
6
5
Via close range reflex (hold hand approx. 2-3 cm in front
of infrared window) it´s possible to activate different
functions like cleaning stop, continuous flow,... (p. 13
Dip-Switch 3, 4, 5, 6). At every close range reflex the
Diagnose LED flashes.

Back side:

3
4
6
Connection of external push-button
4
5
Power supply
6
Magnetic valve
7
Dip-Switch
5