Herunterladen Inhalt Inhalt Diese Seite drucken

Diagnostics And Fault Finding; Resetting A Trip Condition; Trip Diagnostics - Parker 631 Digital Produkthandbuch

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

D
IAGNOSTICS AND
7

Resetting a Trip Condition

Trip Diagnostics

Display Explanation
no display
system ready to operate
system active
internal stop
deactivation via serial interface
Internal stop
Active input is activated
switching on
631 Digital Servo Drive
The seven-segment display is
illuminated when the servo drive is
powered-up. It provides information on
the state of the drive, active trips, and
assists in fault finding.
Remember to remove the protective
film covering the display when
installing the drive.
Figure 7-1 Diagnostic Display
There are two options:
1. Switch the supply voltage OFF and ON
2. Use EASYRIDER
Ready *
(output X10.5)
off
on
off
-
off
with

Diagnostics and Fault Finding

F
F
AULT
INDING
Diagnostic
Display
Warning *
(output
X10.6)
off
off
off
-
off
X
2
0
X
4
0
X 3 0
X 15 /R S2 32
Comment
Is the supply voltage present?
Are the external fuses ok?
regulator ready
not active
output stage active, no interference
• Re-start the drive
or perform a RESET and activate
the drive
Deactivation via BIAS command
• Switch ACTIVE X10.7
to Low and then to High
7-1
X
2
1
X
4
1

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

631

Inhaltsverzeichnis