Failure: The fuse blows in regular intervals.
Cause: The unit connected to the switched socket
outlet draws too much current. The fuses age
too fast.
Remedy: Please refer to examples given in
„Switched socket outlet 7075.12".
Failure: The controller does not control correctly;
the setpoint value cannot be adjusted.
Cause: A battery has been placed in the battery
compartment although the unit is operated on
the switched socket outlet.
Remedy: Remove the 9V battery.
Failure: The controller does not control into the
requested direction
Cause: The jumper in the battery compartment
has been set to the wrong position.
Remedy: Adjust the jumper
(cf. „heating" / „cooling").
Disfonctionnement : Fusion régulière du fusible
après un certain temps.
Raison : L'appareillage raccordé sur la prise
commandée absorbe trop de courant, le fusible
vieillit prématurément.
Solution : Voir exemples „ Prise commandée
7075.12 ".
Disfonctionnement : Le contrôleur ne régule
pas correctement, réglage de la consigne
impossible.
Raison : La batterie est restée présente dans son
logement alors que la prise commandée est
raccordée à l'appareil.
Solution : Retirez la batterie 9V.
Disfonctionnement : Le contrôleur ne régule pas
dans le sens souhaité.
Raison : Jumper du compartiment batterie en
mauvaise position.
Solution : Positionnez le jumper (voir „ chauffer " /
„ refroidir ").