Setting „heating" operation
In order to use the Measuring and Control Station
7028/3 as a control station for heating, the jumpers
in the battery compartment has to be set to the left-
hand position (1). The switched socket outlet will be
switched on (LED ON) as soon as the temperature
measured is abt. 0.2° to 0.4° Celsius (0.4° to 0.8°F)
below the setpoint value adjusted.
Note:
We recommend the use of a controlled heater. Its
internal control is then used as a second safety
level, if the setpoint value is adjusted wrongly at the
measuring instrument.
Example:
The
requested
temperature is 25.5° Celsius (77.9°F) . Adjust the
setpoint value of the Temperature Controller 7028/3
to 25.5° Celsius (77.9°F), and the setpoint value of
the controlled heater to 27° Celsius (80.6°F).
aquarium
water
Fonction „ chauffer "
Afin d'utiliser la station de mesure et de régulation
7028/3 en fonction chauffage, il est nécessaire
de positionner le jumper du logement batterie en
position gauche (1). La prise commandée est
alors enclenchée (LED ON) lorsque la mesure de
température se situe à env. 0,2 à 0,4 °C en-dessous
de la consigne.
Remarque :
Nous
préconisons
thermoplongeur à thermostat. En effet, sa régulation
interne aura pour fonction d'assurer un deuxième
niveau de sécurité contre la surchauffe, en cas de
mauvais réglage de la consigne de température par
exemple.
Exemple pour 25,5°C de température souhaitée :
sur le contrôleur de température 7028/3, affichez la
consigne 25,5°C. Sur le thermoplongeur, affichez la
consigne de 27°C.
toujours
d'utiliser
un
7