Setting „cooling" operation
In order to use the Measuring and Control Station
7028/3 as a control station for cooling, the jumpers
in the battery compartment has to be set to the right-
hand position (2). The switched socket outlet will be
switched on (LED ON) as soon as the temperature
measured is abt. 0.8 to 1 ° Celsius (1.6 to 2°F)
above the setpoint value adjusted.
Note:
In order to cool the aquarium during the hot summer
months, it could be perfect to connect a fan to the
Switched Socket Outlet 7075.12, which should
ensure a gentle breeze at the aquarium surface
causing a considerable increase in evaporation
cooling down the aquarium by 1° to 2° Celsius (2°
to 4° F). In combination with TUNZE Osmolator
and TUNZE ecological pumps, this solution is an
inexpensive alternative to the use of cooling units.
Fonction „ refroidir "
Afin d'utiliser la station de mesure et de régulation
7028/3 en fonction refroidissement, il est nécessaire
de positionner le jumper du logement batterie
en position droite (2). La prise commandée est
donc enclenchée (LED ON) lorsque la mesure de
température se situe à env. 0,1 à 0,2 °C au-dessus
de la consigne.
Remarque :
Dans de nombreux cas de figure, un simple
ventilateur raccordé sur la prise commandée
7075.12 permet de conserver une température
d'aquarium correcte durant les quelques mois
chauds de la saison estivale. Ce dernier doit
générer un flux d'air doux et homogène à la surface
de l'eau ce qui accélère sensiblement l'évaporation
et diminue la température de l'eau de 1 à 2 °C. En
utilisation simultanée avec l'Osmolator TUNZE
et les pompes TUNZE à haut rendement, cette
solution est une alternative idéale à l'utilisation de
groupes de refroidissement.