Thermo 50
7.3.
Metering pump
The metering pump is a combined delivery, metering and shutoff system
and is subject to specific installation criteria (see Figs. 7, 12 and 13).
Preferably
15° - 90°
Fig. 12: Metering pump DP 2
Installation position
Fig. 13: Metering pump DP 30
Installation position
7.3.1.
Installation position
Before installing the metering pump, ensure that the maximum pressure
occurring at the pickup point is less than 0.2 bar.
It is advisable to install the metering pump in a cool place. The
permissible ambient temperature must not exceed + 20 °C at
any time during operation.
Metering pump and fuel lines must not be installed within range of
radiated heat from hot vehicle parts. A heat shield must be used if
applicable. The pump should preferably be installed near the tank.
7.3.2.
Installation and attachment
The metering pump must be secured with a vibration-damping suspension.
Its installation position is limited as shown in Figs. 12 and 13 in order to
ensure effective auto-bleeding.
7.4.
Sticker
The sticker "Switch off heater before refuelling" must be affixed at a
suitable point.
7.5.

Fuel filter

Only a Webasto filter, order no. 487 171, is allowed to be used if the fuel
is expected to be contaminated. Install vertically if possible, however at
least horizontally.
NOTE:
Note the installation position and direction of flow.
Fig. 14: Fuel filter
www.butlertechnik.com
Fuel supply
0° - 90°