or chemical agents or detergents containing solvents.
Periodically, check the technical safety of the tester.
It can be assumed that correct operation is no longer possible if:
-
the device is visibly damaged,
-
if the device was stored under unfavourable conditions for a long period of time
-
if it was exposed to extraordinary stress caused by transport
-
the test function, described above, does not work as it should.
Do not try to open the casing, apart from the battery compartment.
DISPOSAL
a)
Product
Electronic devices are recyclable waste and must not be disposed of in the household
waste.
At the end of its service life, dispose of the product according to the relevant statutory
regulations.
Remove any inserted (rechargeable) batteries and dispose of them separately from
the product.
b)
(Rechargeable) batteries
You as the end user are required by law (Battery Ordinance) to return all used batteries/
rechargeable batteries. Disposing of them in the household waste is prohibited.
Contaminated (rechargeable) batteries are labelled with this symbol to indicate that
disposal in the domestic waste is forbidden. The designations for the heavy metals
involved are: Cd = Cadmium, Hg = Mercury, Pb = Lead (name on (rechargeable)
batteries, e.g. below the trash icon on the left).
Used (rechargeable) batteries can be returned to collection points in your municipality,
our stores or wherever (rechargeable) batteries are sold.
You thus fulfil your statutory obligations and contribute to the protection of the environment.

TEchNIcAL DATA

Operating voltage ............................................. 2 x alkaline micro batteries (AAA)
Power consumption .......................................... approx. 32 mA
Magnetic fields .................................................. AC, DC (also permanent magnets)
Detectable inductance (H = Henry) .................. 63 H, 98 H, 401 H, 810 H
Weight .............................................................. 48 g
Protection class ................................................ 2 (double or reinforced insulation)
Working temperature range .............................. -10 to +50 °C
Relative humidity .............................................. < 95 % rh (non-condensing)
Storage temperature ......................................... -10 to +50 °C
Max. operating altitude ..................................... 3000 m
Legal notice
These operating instructions are a publication by Voltcraft®, Lindenweg 15, D-92242 Hirschau/Germany, Phone +49 180/586 582 7
(www.voltcraft.de).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data processing
systems require the prior written approval by the editor. Reprinting, also in part, is prohibited.
These operating instructions represent the technical status at the time of printing. Changes in technology and equipment reserved.
© copyright 2012 by Voltcraft®