In case the angle indicator 41 is not in a line with
the 0° mark of the scale 44 after the adjust-
ment, loosen the screw 45 using a commercial
Phillips screwdriver and align the angle indica-
tor along the 0° mark.
Setting the Standard Bevel Angle 45°
(Vertical)
– Bring the power tool into the working posi-
tion.
– Turn the saw table 6 until it engages at 0°.
– Loosen the clamping lever 19 and tilt the tool
arm leftward to the stop (45°) by the handle
2.
Checking: (see figure R1)
– Set an angle gauge to 45° and place it on the
saw table 6.
The leg of the angle gauge must be flush with
the saw blade 36 over the complete length.
Adjusting: (see figure R2)
– Loosen the lock nut of the stop screw 18 us-
ing a commercial box-end or open-end span-
ner (size 13 mm).
– Screw the stop screw in or out until the leg
of the angle gauge is flush with the saw blade
over the complete length.
– Retighten the clamping lever 19 again.
– Afterwards, retighten the lock nut of the stop
screw 18 again.
In case the angle indicator 41 is not in a line with
the 45° mark of the scale 44, firstly check the 0°
setting for the bevel angle and the angle indica-
tor again. Then repeat the adjustment of the 45°
bevel angle.
Bosch Power Tools

Transport

Before transporting the power tool, the follow-
ing steps must be carried out:
– Bring the machine into the transport posi-
tion.
– Remove all accessories that cannot be
mounted firmly to the power tool.
If possible, place unused saw blades in an
enclosed container for transport.
– Carry the machine by the transport handle 23
or hold it by the recessed grips 15 on the
sides of the saw table.
When transporting the power tool, use only
the transport devices and never use the
protective devices.

Maintenance and Service

Maintenance and Cleaning

Before any work on the machine itself, pull
the mains plug.
If the machine should fail despite the care taken
in manufacturing and testing procedures, repair
should be carried out by an after-sales service
centre for Bosch power tools.
In all correspondence and spare parts order,
please always include the 10-digit article
number given on the type plate of the machine.
Cleaning
For safe and proper working, always keep the
power tool and its ventilation slots clean.
The retracting blade guard must always be able
to move freely and retract automatically. There-
fore, always keep the area around the retracting
blade guard clean.
Remove dust and chips after each working pro-
cedure by blowing out with compressed air or
with a brush.
Clean the roller 20 regularly.