12 Technical specifications
Device designation:
Supply voltage:
Minimum load:
Maximum switching capacity:
Current consumption:
Power consumption in standby:
Dimming method:
Kind of load:
Radio frequency:
Receiver class:
Typ. open area RF range:
Duty cycle:
Maximum transmit power:
Operating mode:
Switch type:
Degree of protection:
Protection class:
Withstand voltage:
Ambient temperature:
Dimensions (W x H x D):
Weight:
38
HM-LC-Dim1L-Pl-3
230 V/50 Hz
25 VA
250 VA
1.1 A (max.)
0.8 W
Phase control
ohmic and inductive
lamp load
868.3 MHz
SRD Class 2
> 100 m
< 1 % per h
10 mW
S1
independently
mounted switch
IP20
I
2500 V
-10°C to +35°C
63 x 125 x 40 mm
(not incl. plug)
205 g