3.3.1. Data plate
3.3.2. Motor
The motor consists of a stator and the motor shaft with the rotor set. The lead for supplying power is designed for
the maximum mechanical power in accordance with the characteristic curve or data plate of the pump. The cable
entries and the lead are sealed watertight against the conveyed medium. The shaft bearings are robust,
maintenance-free and permanently greased roller bearings.
General motor data
Mode of operation of an immersed motor
Permissible temperature of medium
Insulation class
IP Code
Standard cable length
Voltage
Warning of rotating blade wheel
Do not touch the rotating blade wheel or reach through the discharge outlet into the pump chamber.
During operation, never reach into the pump chamber or touch rotating parts. Before performing
maintenance or repair work, shut the machine off and let the rotating parts come to a standstill.
Motor cooling
The cooling jacket ensures adequate motor cooling even if the motor housing is exposed.
3.3.3. Pump housing
The pump housing is fitted with a discharge outlet G 1 ¼" A.
3.3.4. Blade wheel
The blade wheel is fastened on the motor shaft and is driven by it. The blade wheel is an open multivane impeller
No.
Description
1
Pump type
2
Part No.
3
Serial No.
4
Frequency
5
Voltage
6
Motor input
7
Nominal current
8
Motor Speed
9
Insulation class
10
Motor protection
11
Year of construction (JJ)
12
Norm
13
Hmax (max. head)
14
Submersion depth
15
Qmax (max. flow)
16
max. liquid temperature
S1
35°C
H
IP68
10 m
230V / 1Ph / 50Hz
27