5 Mounting and connection
Check whether the permissible air gap (d) is maintained on the subsequent instal-
lation of the MiniCODER. The value is dependent on the type and tooth wheel
module.
Air gap table
Type
GEL 2444␣␣␣␣3␣␣␣␣␣
GEL 2444␣␣␣␣5␣␣␣␣␣
Mill the recess and make the bores in the mounting carefully and remove chips
completely.
5.2
Fitting target wheel
Mount the target wheel on the shaft; during this process pay attention to the posi-
tion of the signal track and reference track.
After mounting, check the mounting tolerances are met.
5.3
Mounting MiniCODER
5.3.1
Cleaning mounting surfaces
Thoroughly clean the mounting surfaces on the machine and on the MiniCODER
as well as the mounting screws to obtain good electrical conductivity.
Ensure the measuring scale and installation space are free of contamination and
chips from machining.
54
Fitting target wheel
Module
preset measure ± distance tolerance
0.3
0.5
Lenord + Bauer
Air gap d,
0.15 mm ± 0.02 mm
0.20 mm ± 0.03 mm
GEL 2444