Lenord + Bauer
6
Removal
If a functional MiniCODER is to be removed for a modification, pay attention to the
following:
– Ensure the sensitive measuring surface does not come into contact with other
objects to prevent damage.
– Only touch the connector pins and wires if you are suitably earthed, for exam-
ple using an ESD wrist strap, to prevent damage to the electronic components
due to electrostatic discharge.
GEL 2444K␣P␣␣␣␣␣␣␣:
If a testing and programming unit GEL 211 is available, reset the MiniCODER to
the factory settings.
Switch off the power supply.
Disconnect the connection.
Uncover the connection cable.
Insert the distance gauge in the air gap.
Undo and remove the fastening screws for the MiniCODER.
Avoid impacts against the measuring surface by other objects.
Take the MiniCODER out of the mounting.
If the MiniCODER is to be used again, store it in the original packaging or an
equivalent container with protection.
GEL 2444
6 Removal
57