Herunterladen Inhalt Inhalt Diese Seite drucken

Lenord, Bauer MiniCODER GEL 2444 Betriebsanleitung Seite 49

Drehzahl- und positionssensoren
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Lenord + Bauer
1
MiniCODER with flying lead or connector
1
2
MiniCODER with panel-mounting socket (e.g. GEL 2444)
1
Machine (e.g. spindle)
2
MiniCODER
3
Panel-mounting socket
4
Evaluation electronics
5
Equipotential bonding cable (only in case of extreme interference)
a
Connecting cable with outer screen and three inner screens
b
Inner screens (3×)
c
Outer screen
 The MiniCODER is part of a machine or plant. Integrate the equipotential bonding
for the MiniCODER into the overall screening concept.
 Lay the signal cables and control cables physically separate from the power
cables. If this configuration is not possible, use screened twisted pair cables
and/or lay the MiniCODER cable in a steel conduit.
 Make sure that external protective measures against surge voltages have been
implemented (EN 61000-4-5).
GEL 2444
Measuring system
2
5
3
c
3
1
Machine
2
MiniCODER
3
Evaluation electronics
4
Control cables
5
Equipotential bonding
cable (only in case of
extreme interference)
4
b
a
c
5
3 Prevention of damage
4
+5 V
Signal
GND
PE
49