Assembly
1.
Flush the pipes, close shut-off valve afterwards.
2.
Remove blank plug.
3.
(a) Connect the adapter with the magnetic valve and
(b) insert magentic valve and tighten by hand!
4.
Switch off power! Feed the connection cable into the flush-mount
set and connect plug.
5.
Connect the power unit with connection cable and insert power
supply into flush mount set.
6.
Connect magnetic valve with the electronics.
Pay attention to the plug connections!
7.
Connect power unit with electronics.
Pay attention to the plug connections!
8.
Switch on power and open shut-off valve
(causing the safety locking mechanism of the magnetic valve).
Overview – flushing quantities
Pressure
1 bar
2 bar
3 bar
4 bar
5 bar
OCEAN U8
2,0
5,5 s
4,5 s
3,0 s
2,5 s
2,5 s
Flush volume in liters
3,0
7,0 s
5,5 s
4,5 s
4,0 s
4,0 s
Urinal control
4,0
10,0 s
7,5 s
6,0 s
5,5 s
5,0 s