Mounting

HYGIENE RISK!
The housing surfaces have peak-to-valley height < 0.8 μm. Damage to the surfaces favour the later formation of micro-organism
deposits during operation. Consequently, adopt appropriate measures to protect the housing surfaces from damage during
mounting. Install the HD compact enclosure only standing (inclined roof at the top) – this is required to ensure a hygiene-conform
operation.
Ø 16.5

Wall mounting with spacer brackets

1
1
1
1
Model No. HD H mm
Model No. HD H mm
1302.600/.500
330
1306.600/.500
1320.600/.500
1307.600/.500
1308.600/.500
1310.600/.500
ma_hgd002_gb.fm -
32
von 35
SW24
Model No. HD H mm
1316.600/.500 1010
410
1317.600/.500 1210
525
625
DANGER!
If the wall spacer brackets are
● Placed incorrectly
● Not used in sufficient quantity
● Fastened with an incorrect tightening torque
there is the danger of the occurrence of severe or lethal injuries
caused by the HD compact enclosure falling down. It is also possi-
ble that the rear panel of the housing distorts. Consequently,
ensure that you observe the specifications described below.
HYGIENE RISK!
If the HD compact enclosure is fastened to an uneven wall
using wall spacer brackets, there is the danger of gaps
occurring on the seal that are critical for the hygiene.
Consequently, fasten the HD compact enclosure only on even surfaces
or adopt additional sealing measures to ensure a hygienic fastening.
Distance from wall mm
50
Model No. HD
4000.100
1
SW 24
M
= 10 Nm
D
Rittal Hygienic Design assembly instructions