Technische Angaben
8.5 Hardwarebeschreibungen
8.5.1.2

CFast

Pin
S1
S2
S3
S4
S5
S6
S7
PC1
PC2
PC3
PC4
PC5
PC6
PC7
PC8
PC9
PC10
PC11
PC12
PC13
PC14
PC15
PC16
PC17
232
Kurzbezeichnung
Bedeutung
SGND
Signal GND (ground for signal integrity)
A+
SATA Differential
A-
SATA Differential
SGND
Signal GND (ground for signal integrity)
B-
SATA Differential
B+
SATA Differential
SGND
Signal GND (ground for signal integrity)
CDI
Card Detect In
GND
Device GND
TBD
TBD (not connected)
TBD
TBD (not connected)
TBD
TBD (not connected)
TBD
TBD (not connected)
GND
Device GND
LED1
LED Output (not connected)
LED2
LED Output (not connected)
IO1
Reserved Input/Output (not connected)
IO2
Reserved Input/Output (not connected)
IO3
Reserved Input/Output (not connected)
PWR
Device Power (3.3V)
PWR
Device Power (3.3V)
GND
Device GND
GND
Device GND
CDO
Card Detect Out
SIMATIC IPC477D, IPC477D PRO