Herunterladen Inhalt Inhalt Diese Seite drucken

ECTIVE SI Series Montage- Und Betriebs-Anleitung Seite 54

Sinus/sine inerter
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Symptom
acoustic signal sounds
3x and red LED flashes
every 8 sec .
acoustic signal sounds
4x and red LED flashes
every 8 sec .
acoustic signal sounds 5x
and red LED flashes 5x
every 8 sec .
red LED flashes
permanently
Caution!
Immediately eliminate error sources!
Make sure that error sources are eliminated . Multiple restarts due to unsolved errors
can destroy the inverter .
Especially prevent short circuits and polarity reversals because they can destroy the
device despite protection .
52
[
ECTIVE
SINUS/SINE INVERTER – SI-/TSI-SERIES
®
Possible reason
total undervoltage
(see table)
input voltage too high
(see table)
inverter overheated
maximum short­term
power reached
Solution
1 . check charging status
of battery, charge if
necessary
2 . check compatibility
of battery cable, use
higher cross section if
necessary
3 . check if conductive
parts (cables, pole termi­
nals, lugs) are damaged
1 . check voltage
2 . check charging voltage
of battery charger
3 . check if there are un­
wanted voltage sources
check ventilation, if
damaged, call support
check if ventilations slits
are free
check if ambient air is cool
enough
reduce power
switch off inverter
reduce power
cool down inverter
]

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Tsi series

Inhaltsverzeichnis