ECTIVE
SINUS/SINE INVERTER – SI-/TSI-SERIES
®
Model
SI/TSI
200
approx . 1,00 A
250
approx . 1,10 A
300
approx . 1,20 A
Recommended surrounding conditions
Operating temperature
Storage temperature
Relative humidity
☝
Please note!
Please mind the starting current!
Keep in mind that inductive devices (for example power drills or refrigerators etc .) often
need a 3–10 times higher power at the beginning than indicated on the descriptive
type plate . The maximum power of this short period should not surpass the maximum
power of the inverter .
☝
Please note!
Listen to the acoustic signal!
In case of overload an acoustic signal will sound . If the needed power is not reduced to
the maximal continuous output, the inverter will shut down automatically .
☝
Please note!
Output losses because of heat
An ambient temperature over 40°C (for ex . due to heat at the installation site or direct
sunlight) can lower the specified output and efficiency .
12 V
24 V
approx . 0,50 A
approx . 0,55 A
approx . 0,60 A
15 °C bis 40 °C
40 °C bis 85 °C
20 % ~ 90 %
]
48 V
approx . 0,25 A
approx . 0,28 A
approx . 0,30 A
43