Operation
Connect the machine to a suitable power source
according to the specifi cation plate on the mach-
ine. If the electrical cord get damage it should be
replaced.
The fi lter should be cleaned 1-2 times per day with
continues running of the machine or when the fi lter
monitor is in the red area:
1.
Start the machine.
2. Close the shutter valve for inlet.
3. Open and shut the cleaning fl ap with quick
movement 8-10 times.
4. Open the shutter valve.
Service
With cleaning and maintenance on the machine,
the power cable should be disconnected from the
supply.
-
The fi ne fi lter should be changed at least once
per year. Use only original spare parts.
-
If the machine is used with a microfi lter/HEPA
fi lter, this should be changed every 300 run-
ning hours. Use breathing protection when
changing the fi lter. Care must be taken during
the fi lter change not to expose unprotected
persons to harmful dust.
-
Used fi lters should be sealed in a plastic sack
and disposed properly.
-
Check regularly that the electric cable isn´t
damaged.
Accessories
Description
Suction hose
Microfi lter with HEPA
Fine Filter, Polyester
5. If the fi lter condition meter reads green - conti-
The container under the cyclone should be emp-
tied when it is 2/3 full.
The maximum capacity is 60 kg.
The DC 3800i should be performance tested at
least once per year because it may be used with
hazardous materials. Worn parts must be repla-
ced. Dustcontrol is only responsible for machines
that are equipped with original spare parts.
The turbopump has a very long maintenance free
service life. After approximately 10 000 running
hours, the radial seal between the motor and pump
housing should be greased. Bearings and seals in
the motor and turbopump should be checked and
lubricated. Parts worn beyond serviceable toleran-
ces should be replaced with genuine spare parts.
Part no
2401
Other accessories - see I-line accessories and
42024
Dustcontrol catalogue.
42025
DC 3800i - 10
nue work.
If the fi lter condition meter reads red - clean
pulse again.
If the fi lter condition meter still reads red -
change the fi lter No 42025.