3. Trouble Shooting

3.1. Blind rivet cannot be set

Causes
– Battery empty
– Jaws dirty or worn
– Jaw assembly loose
– Jaw pusher spring weak
– When trigger is pressed, non-function (red light)
3.2. No spent mandrel discharge
Causes
– Wrong nosepiece
– Nosepiece worn
– Mandrel jammed in jaws
– Dirt inside head
– Spent mandrel container full
– Mandrel guide tube blocked
3.3. Red light indicates faults
3.3.1. when trigger is pressed
Causes
– Tool not in front position
3.3.2. while pulling the rivet
Causes
– Overloading
– Overheating of electronic control
– Battery empty
3.3.3. after releasing the trigger
Causes
– Jaw assembly does not reach the front
position
3.3.4. Note
– In case of trouble indicated by the red light, which can't be eliminated as described above, the tool has
to be repaired by trained personnel only or to be returned to the distributor or the manufacturer.
Remedy
charge, if necessary replace
clean and lubricate or replace (see 1.8.)
tighten (see 1.8.)
replace
see par. 3.3.
Remedy
exchange according to table 1.4.
replace
loosen the mandrel, clean jaws and jaw
housing, lubricate surface, respectively
replace jaws (see 1.8.)
clean (see 1.8.)
take off and empty
remove clogged mandrels and check for free
ejection (see 1.8.)
Remedy
release the trigger
Remedy
check working capacity according to table 1.4.
allow the tool to cool off in air
charge or replace
Remedy
screw on the jaw assembly tightly
(see 1.8. and 3.2.)