Herunterladen Inhalt Inhalt Diese Seite drucken

How Do You Install Your Oven; Electrical Connection - DeDietrich DOP440 Serie Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 46
99633781ml.qxd
07/09/04
H
ow do you install your oven?

Electrical connection

Monophase line 220-240 V ~
16A fuse or differential
Electrical outlet
2-prong receptacle
+ ground lead
CEI Standard 60083
Before making the connection, ensure that the wires in your elec-
trical installation have enough cross-sectional area to properly
supply electricity to the appliance.
The fuse in your set-up must be 16 amperes.
The electrical connection should be performed before the appliance is installed in
the cabinet.
• The oven must be connected with a power cable (standardised) with three 1.5
2
mm
conductors (1 ph +1 N + ground) that must be connected to a monophase
220-240 V network via a CEI 60083 standardised receptacle (1 ph +1 N + ground
lead) or in accordance with installation rules. The safety wire (green-yellow) is
connected to the appliance's terminal
lead of the electrical set-up.
• In the case of connections with an electric receptacle, it must remain accessible
after installation of the appliance.
• The oven's neutral conductor (blue wire) must be connected to the network's
neutral conductor.
14:38
Page 29
circuit breaker
Power cable
approximately
1.5 m in length
Monophase 20A Counter
220-240 V ~ 50 Hz
and must be connected to the ground
GB
29

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Dop440xDop440-serie

Inhaltsverzeichnis