Herunterladen Inhalt Inhalt Diese Seite drucken

Specifications - Monacor VNC-2044 Anleitung

Vorschau ausblenden Andere Handbücher für VNC-2044:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

®
When calling the camera, first the log-in screen appears in
which the user name and the password have to be entered
(preset for both inputs: admin). Individual log-in data can
later be defined in the camera settings. At least the pass-
word should be changed against unauthorized access.
For the first connection set-up via the IE, the IE downloads
the required extensions (ActiveX control elements) from
the camera and installs them on the computer. If neces-
sary, the safety settings of the IE must be eased before
installation so that this procedure is admitted.
When the connection to the camera is made, the present
camera picture shown in fig. 3 is displayed, with the fol-
lowing operating possibilities:
display size
option streaming 1 or 2 (to be configured)
option for the audio transmission to the camera
number of the present accesses to the camera
relay: for manual triggering the relay output
button to call the settings (Setup)
snapshot function to memorize a snapshot as a picture
(with pre-view window)
Click the camera picture with the right mouse button to
insert the following menu:
Snapshot – storing of a snapshot as a picture
Record Start/ Stop – start / stop of a video recording on
the PC
Mute – muting of the camera sound
Full Screen – full screen view (double-click to go back)
Zoom – cutout enlargement
To configure the camera, click the symbol above
settings are displayed (
fig. 4). Here the language for
the complete user interface can be changed as well ( ).
Select the desired category for the settings via the defini-
tions at the upper edge ( ). When moving the mouse
pointer across the definition, further subcategories are
opened.
To return to the start view (camera picture) click the sym-
bol next to
.
Further information about the versatile configuration facil-
ities of the camera can be found in the English documen-
tation of the supplied CD.
7 Reset of the Camera
The camera can be reset to its factory settings. Then all
changes of the camera settings made by the user are lost.
1) Disconnect the camera from the power supply.
2) Connect the pink cable "Connecting the default wire ..."
(8) to the terminal GND of the terminal block (4) and re-
establish the power supply.
3) After the starting procedure of the camera (approx.
30 s), disconnect the connection.
The camera is now reset to the static IP address
192.168.1.200, the user name and the password for the
log-in is: admin
8 Adjusting Focal Length and Focus
Turn the screws at the lower side to adjust the focal length
[zoom (13)] and the sharpness [focus (14)]. For presenta-
tion without delay a monitor at the BNC connection (5) is
useful.
VNC -1044

9 Specifications

Image sensor: . . . . . . . . . . . CMOS, 8.5 mm (
Lens: . . . . . . . . . . . . . . . . . . 1 : 1.2 / 3.6 – 16 mm
Minimum illumination: . . . . . . 0.1 lx (LEDs off)
Compression procedure: . . . MPEG-4 H.264, MJPEG
Video streaming: . . . . . . . . . 3-fold
Resolution: . . . . . . . . . . . . . . 15 pictures / sec max. at
Protocols: . . . . . . . . . . . . . . . Bonjour, TCP/ IP, DHCP,
Network: . . . . . . . . . . . . . . . . Ethernet 10 / 100 Mbits / s
. The
®
MONACOR INTERNATIONAL GmbH & Co. KG • Zum Falsch 36 • 28307 Bremen • Germany
Copyright
©
by MONACOR INTERNATIONAL. All rights reserved.
Order No. 18.3200
1
")
3
1600 × 1200 pixels
PPPoE, ARP, ICMP, FTP,
SMTP, DNS, NTP, UPnP,
RTSP, RTP, RTCP, HTTP,
HTTPS, TCP, UDP, 3GPP/
ISMA, RTSP, ONVIF
or WLAN 802.11 b / g / n

Ž

Microphone input: . . . . . . . . . 3.5 mm jack
Audio output: . . . . . . . . . . . . 3.5 mm jack, mono,
line level
Video output: . . . . . . . . . . . . 1 Vpp / 75 Ω, BNC
Relay output: . . . . . . . . . . . . 24 V /1 A max.
Ambient temperature: . . . . . . -30 °C to +50 °C
Protective class: . . . . . . . . . . IP 66
Power supply: . . . . . . . . . . . . 12 V , 1 A via
supplied PSU
Dimensions: . . . . . . . . . . . . . ∅ 86 mm × 190 mm
Weight: . . . . . . . . . . . . . . . . . 3 kg
Subject to technical modifications.
A-1396.99.01.12.2012

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis