Longer break
 Close the hand spray gun.
 Push the safety catch on the trigger gun
forwards slightly.
Appliance with
holder for trigger
gun:
 Place the trigger
gun into the holder.
The pump stops.
 Remove trigger
gun from the hold-
er.
The pump starts.
 Release the trigger gun. To do so, push
the safety catch towards the back.
 Open the hand spray gun.
Turn off the appliance
 Shut off water supply.
 Open the hand spray gun.
 Switch on the pump with the power
switch and allow to run for about 5-10
seconds.
 Close the hand spray gun.
 Set the appliance switch to "0/OFF".
 Pull main plug out of socket with dry
hands only.
 Activate hand spray gun until device is
pressure less.
 Secure the trigger gun. To do so, push
the safety catch towards the front.

Frost protection

ATTENTION
Frost will destroy the not completely water
drained device.
Store the appliance in a frost free area.
If you cannot store it in a frost-free
place:
 Drain water.
 Pump in conventional frost protection
agents through the appliance.
Note:
Use normal glycol-based anti-freezing
agents for automobiles.
Observe handling instructions of the anti-
freeze agent manufacturer.
 Operate device for max. 1 minute until
the pump and conduits are empty.
22
Appliance without
holder for trigger
gun:
 Set the appliance
switch to "0/OFF".
The pump stops.
 Set the appliance
switch to "I".
The pump starts.
 When transporting in vehicles, secure
the appliance according to the guide-
lines from slipping and tipping over.
CAUTION
Risk of personal injury or damage! Mind the
weight of the appliance during transport.
ATTENTION
Protect the trigger from damage during

transport.

CAUTION
Risk of personal injury or damage! Consider the
weight of the appliance when storing it.

Care and maintenance

DANGER
Risk of injury by inadvertent startup of ap-
pliance and electrical shock.
Prior to all work on the appliance, switch off
the appliance and pull the power plug.
Note:
Used oil must only be disposed of by the
designated collection points. Please turn in
used oil there. Polluting the environment
with used oil is prosecutable.
Safety inspection/ maintenance
You can sign with your dealer a contract for
regular safety inspection or even sign a
maintenance contract. Please take advice
on this matter.
Before each use
 Check connection cable for damages
(risk of electrical shock); get the dam-
aged connection cable replaced imme-
diately by an authorised customer ser-
vice person/ electrician.
 Check the high pressure hose for dam-
ages (risk of bursting).
Please arrange for the immediate ex-
change of a damaged high-pressure
hose.
 Check appliance (pump) for leaks.
3 drops per minute are permitted and
can come out from the lower side of the
appliance. Call Customer Service if
there is heavy leakage.