Herunterladen Inhalt Inhalt Diese Seite drucken

Proper Use - Kärcher HD 7/16-4 Cage Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für HD 7/16-4 Cage:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
– There is a recoil pressure arising from
the water jet that comes out from the
spray pipe. The angular spray pipe
brings about an upward force. Hold the
gun and the spray pipe tightly.
– The recoil and bending forces may be
different if you are using angular spray
devices.
The engine is to be brought to a standstill
and the appliance is to be fastened properly
during transportation.
Maintenance
– Switch off the appliance and, in case of
appliances connected to the mains, pull
out the power cord before cleaning and
performing any maintenance tasks on
the machine.
– Relieve the high pressure system of all
pressure prior to all work on the appli-
ance and the accessories.
– Maintenance work may only be carried
out by approved customer service out-
lets or experts in this field who are famil-
iar with the respective safety regula-
tions.
– Mobile industrial apliances are subject
to safety inspections according to the
local regulations (for e.g. the following
are applicable in Germany: VDE 0701).
Accessories and Spare Parts
– To avoid risks, all repairs and replace-
ment of spare parts may only be carried
out by the authorised customer service
personnel.
– Only use accessories and spare parts
which have been approved by the man-
ufacturer. The exclusive use of original
accessories and original spare parts
ensures that the appliance can be oper-
ated safely and trouble free.
18
Transport
Use this high pressure cleaner exclusively
for
– cleaning with a high pressure jet without
detergent (e.g. cleaning of facades, ter-
races, garden appliances, vehicles and
similar objects).
For stubborn dirt, we recommend the use of
the dirt blaster as a special accessory.
Quality requirements for water:
ATTENTION
Only clean water may be used as high
pressure medium. Impurities will lead to in-
creased wear and tear or formation of de-
posits in the appliance.
If recycled water is used, the following limit
values must not be exceeded.
pH value
electrical conductivity *
settleable solids **
total suspended solids *** < 50 mg/l
Hydrocarbons
Chloride
Sulphate
Calcium
Total hardness
Iron
Manganese
Copper
Active chloride
free of bad odours
* Maximum total 2000 µS/cm
** Test volume 1 l, settling time 30 min
*** no abrasive substances
– 4
EN

Proper use

6,5...9,5
Conductivity
fresh water
+1200 µS/cm
< 0,5 mg/l
< 20 mg/l
< 300 mg/l
< 240 mg/l
< 200 mg/l
< 28 °dH
< 50 °TH
< 500 ppm
(mg CaCO
< 0,5 mg/l
< 0,05 mg/l
< 2 mg/l
< 0,3 mg/l
/l)
3

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis