4 Operation
4.4 Setting up the MASTER-
SLAVE on the VAR 60/1 DW
6
5
4.4.1 Initialising the product
1. Switch on the product.
◁
The LED lights up for 10 seconds.
2. Press the button for eco mode (1) five
times while the LED is lit up.
◁
The LED lights up and remains lit.
◁
The ventilation unit has been initial-
ised.
3. Switch off the ventilation unit.
4.4.2 Assigning the code
Applicability: VAZ RCW
1. Switch on the first ventilation unit.
◁
The ventilation unit waits until you
enter the eight-digit code.
◁
The LED on the ventilation unit
flashes red and white.
2. Use the six buttons (1) to (6) to select
an eight-digit code, but do not use the
same number eight times.
106
1
3. Note down the code.
2
3
4. Enter the code.
◁
The LED on the ventilation unit
flashes red: The code is assigned to
the ventilation unit.
▽
The LED on the ventilation unit
4
lights up red for 3 seconds: The
code that is entered is invalid.
– If the LED on the ventilation unit
5. Set up the ventilation unit as the
MASTER. (→ Page 106)
6. Switch on the closest ventilation unit
and enter the code.
7. Set up this ventilation unit as the
SLAVE. (→ Page 107)
8. Repeat steps 5 and 6 for all other vent-
ilation units.
4.4.3 Setting up a ventilation unit as
the MASTER
Applicability: VAZ RCW
▶
Press the button for eco mode (1) twice
in order to set up the ventilation unit as
the MASTER.
Operating instructions 0020236700_04
Note
The code is required when you
set up other ventilation units.
flashes red and white again, you
can enter a new code.
Note
Only one ventilation unit may be
set up as the MASTER.