Safety instructions

Only use the machine if it is in perfect technical
condition
Protect the machine against moisture
Do not deactivate safety and protective devices
Wear protective glasses and ear defenders
Wear long trousers and sturdy shoes
Keep your hands and feet away from the blade
system
Do not place your hands and feet close to any ro-
tating parts
Keep third parties away from the danger area
Remove foreign bodies from the working area
When leaving the machine:
Switching off the motor
Wait for the blade system to come to a stop
Disconnect from the mains
Do not leave the machine unsupervised
Children, or other people who are not familiar with
the operating instructions, are not allowed to use
the machine
The machine must not be operated by persons un-
der the influence of alcohol, drugs or medication
Comply with the local regulations on minimum age
of people operating the machine

Installation

Assemble the machine in accordance with the illustra-
tions (01, 02).
Important!
The machine is not allowed to be operated unless it
has been fully assembled.

Start-up

Important!
Always perform a visual check prior to start-up. Do
not operate the machine if the blade system and/or
the fastening parts are loose, damaged or worn.
Comply with working time regulations in force in
your country
Always comply with the operating instructions
supplied from the engine manufacturer
16

Power cable safety

Only use rubber-sheathed cables with quality
H05RN-F acc. to DIN/VDE 0282 with a conductor
cross section of 3 phases of 1.5 mm² each.
The type designation must be marked on the pow-
er cable. The plug and coupling socket must be
made from rubber or sheathed in rubber, and be in
accordance with DIN/VDE 0620.
Only use a power cable with sufficient length.
The power cable, plug and coupling socket must
be protected against splash water.
Repairs on the power cable, plug and coupling
socket are only allowed to be carried out by au-
thorised specialist companies. A defective power
cable (e.g. with cracks, cuts, crushed or kinked
points in the insulation) is not allowed to be used.
Protect the plug connections against moisture.
Danger!
Do not damage or cut the power cable.
If the power cable is damaged, immediately discon-
nect it from the mains.
Electrical requirements
230 V/50 Hz alternating current
Minimum cross section
Power cable = 1.5 mm²
Minimum fusing of mains connection = 10 A
Residual-current circuit breaker (RCCB)
Maximum tripping current = 30 mA.
Establishing the mains connection (05)
1. Connect the coupling part of the power cable to
the plug on the safety pushbutton switch (a).
2. Coil the power cable into a loop and hook it into
the cable strain relief (b). Leave the loop long
enough for the cable strain relief to be able to slide
from one side to the other.
Danger!
Never operate the machine from mains sockets
which do not have a residual-current circuit breaker.
Translation of the original instructions for use

Quicklinks ausblenden:

Werbung