Attention: due to high temperature within the working area of steam jet and at steam outlet, direct skin contact should
be avoided.
- warning! Hot surface!
Silicone must be provided by building constructor. Please keep in mind that maintenance joints may require
cleaning.
02
Equipment
■
Back walls in white made of toughened safety glass with EverClean coating.
■
Frameless glazing on the front made of toughened safety glass (6 mm) with an EverClean coating
■
Roof, made of glass (6 mm).
■
Shower tray (optionally) made of mineral cast Incl. pre-assembled frame
■
Integrated control panel
■
Steam generator with automatic rinse and decalcifi cation. Nominal voltage 230 V, 50/60 Hz
3.3 kW for the rectangular version 1000x1000, 1200x1000, quarter circle and square version 1000x1000
4.0 kW* for the rectangular version 1400x1000, 1600x1000, 1800x1000
■
Steam jet with a condensate drip tray
■
Functional column made of aluminium, two functional columns on the rectangular version 1600x1000, 1800x1000
■
Fittings (chrome-plated) consisting of (per functional column):
Hand shower, rain shower, 6 adjustable back jets, thermosat 1/2˝, 2 shut-off valves (left functional column), 3 shut-off valves
(right functional column).
■
Rain shower and back jets electronically operated
■
Sound Module: Bluetooth, Radio, 2 speakers
■
LED-stripe with colour changer in the roof frame
■
A stool made of stainless steel with PU seat, for the rectangular version 1600x1000 and 1800x1000 two stools
■
Glass frame joints with lifting mechanism
02.01 Fittings technical data
■
Recommended fl ow pressure:
■
Hot water temperature:
■
Recommended hot water temperature:
■
Temperature range:
■
Safety cut-off:
02.02 Steam generator technical data
Steam generator
Voltage
Fuse protection
Line cross section
Water connection (Cold Water + Hot Water)
Steam output
03
Caring for the steam bath/shower cabin
After showering/steaming, rinse the tray and wall element surface with water and wipe down with a damp cloth. Do not use scouring
agents! For occasional thorough cleaning, use a few drops of cleaning agent, e.g. Hoesch Cleaner (item no. 6999 00), on the surface
and rub with a soft, dry cloth. Remove heavier soiling using warm water and liquid cleaning agent or a soap lye. Wipe away scale
deposits using vinegar and water (avoid contact with the fittings!). Observe the manufacturer's instructions if using drain cleaners!
Remove slight scratches or rough areas in glossy surfaces with the Hoesch Sanicryl care set (item no. 699100, follow instructions!).
Remove deep scratch marks or burns on glossy or matt surfaces using fi ne sandpaper (no. 800-1500) or a fi ne steel wool metal eraser
by rubbing carefully in one direction in a large area around the scratch. Treat glossy surfaces only with special polishing cream.
03.01 Caring for the glass panels and profi les
■
After showering, quickly rinse the partition with clean water.
■
Use only a damp rag (never dry) to wipe down the panels and frame. You can also use a squeegee to dry the panels.
■
Only use gentle cleaners such as a weak vinegar and water solution. Never use cleansing powder or cleaners containing
chlorine.
■
Do not use microfi ber cloths. They destroy any coatings and may cause the glass to become scratched.
■
It is a good idea to lightly oil sliding and swinging doors so they remain easy to open.
*
3,3 kW for Switzerland
200-500 kPa
max. 90°C
60-70°C
20-60°C
38°C
,
1000x1000
1200x1000
3,3 kW
16 A
4,2 kg/h
1400x1000
1600x1000
1800x1000
4 kW*
1N~230 V, 50/60 Hz
20 A
3 x 2,5 mm²
R½"
6,5 kg/h
GB