Herunterladen Inhalt Inhalt Diese Seite drucken

Extended Operator Functions - GDO 500S/L Einbau- Und Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Check the automatic cut-out
Automatic cut-out OPEN
In the case of operator systems for doors with openings in the
door leaf (diameter of the opening > 50 mm):
• While the door is running, load the centre of the lower edge of
the door with a 20 kg load.
The door must stop immediately.
Automatic cut-out CLOSED
• Place a 50 mm high obstruction on the ground.
• Drive the door towards the obstruction.
The operator system must stop and reverse when it hits the
obstruction.
Advice:
- The sensitivity of the automatic cut-out is determined
automatically. It can be altered in the extended functions.
- The parameter settings are still saved if the power supply is
interrupted.
Only a reset causes the driving power settings for the OPEN and
CLOSE directions to revert to the factory settings.
8.

Extended operator functions

Caution!
Important factory default settings can be changed using the
extended functions.
All the parameters must be set correctly to avoid damage to
persons or property.
1x >10s
P
1x <1s
P
1x <1s
P
1x <1s
P
GDO 500S/L - 700S/L (#91376)
The operator system is in operating
mode
Call up extended functions / door
operator starts a countdown from 13 - 1 /
keep P pressed!
Let go of P /
programme required driving power
for OPEN direction
Set the required driving power for OPEN
direction with (+) and (-) /
16 settings possible
Save required driving power for OPEN
direction /
programme required driving power
for CLOSE direction
Set the required driving power for
CLOSE direction with (+) and (-) /
16 settings possible
Save required driving power for CLOSE
direction /
programme automatic cut-out for
OPEN direction
Set the automatic cut-out for OPEN
direction with (+) and (-) /
16 settings possible
Save automatic cut-out for OPEN
direction /
programme automatic cut-out for
CLOSE direction
Set the automatic cut-out for CLOSE
direction with (+) and (-) /
16 settings possible
Save automatic cut-out for CLOSE
1x <1s
direction /
P
programme start-up warning
Advice:
The start-up warning can only be used in conjunction with a
signal lamp relay (optional) and a connected-up signalling device
(country-specific).
Set the start-up warning with (+) and (-) /
0 - 7 seconds possible
Save start-up warning /
1x <1s
Programming the Automatic Closing
P
Timer
Advice:
The Automatic Closing Timer can only be used if a photocell is
connected.
The Automatic Closing Timer can be set
with (+) und (-) / 8 settings possible
(see table below)
Available settings for the Automatic Closing Timer:
0
-
-
deactivated
1
15
5
activated
2
30
5
activated
3
60
8
activated
4
15
5
activated
5
30
5
activated
6
60
8
activated
unlim-
7
3
activated
ited
Legend:
LED segment off
LED segment flashes
LED segment flashes rapidly
LED segment lights up
-
Extension of door OPEN time only
through impulse signal
(button, hand transmitter)
Interruption of the door open
duration after the photocell
barrier has been driven past
Closes after the photocell barrier
has been driven past /
closing prevention
11

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

700s/l

Inhaltsverzeichnis